Broad carrier compatibility
Works with the major mobile networks in the U.S., including AT&T, T-Mobile and Verizon, on optimised IoT bands for dependable encrypted transmission.
Model SCL-80A
Cellular body weight monitoring with an enhanced measurement range and clinical-grade resolution.
4G cellular
Works with the major mobile networks in the U.S., including AT&T, T-Mobile and Verizon, on optimised IoT bands for dependable encrypted transmission.
Trusted-endpoint access management permits HIPAA-compliant connections only to pre-approved destinations, and the transmission log meets the data requirements behind CPT 99453 and 99454.
The measurement leaves the scale on its own within seconds; there is no sync button and no phone involved.
Stepping on is the entire workflow, which is what keeps weigh-in adherence high across a cohort.
Instant data sync
Zero-configuration
Easy trend tracking
Encrypted upload completes within a few seconds of the measurement stabilising.
Fleet updates over the air, with no collection round and no downtime for the patient.
Documented integration for telehealth equipment providers and platform builders.
Per-reading records that support Medicare CPT billing documentation without manual reconciliation.
| Model | SCL-80A |
|---|---|
| Measurement | Body weight |
| Maximum capacity | 260 kg / 573 lb |
| Resolution | 0.1 lb / 0.05 kg |
| Stabilisation time | 3–5 seconds |
| Display | Large high-contrast LED, oversized numerals |
| Platform | Tempered glass, alcohol-cleanable |
| Connectivity | 4G LTE Cat M1 / NB-IoT, encrypted uplink |
| Carrier support | AT&T, T-Mobile, Verizon; optimised IoT bands |
| Network control | Trusted-endpoint allow-list; HIPAA-compliant destinations only |
| Firmware | Over-the-air (OTA) update |
| Data log | Per-reading timestamped records for CPT 99453 / 99454 |
| Integration | Open API and SDK |
| Power | 4 × AA alkaline |
| Dimensions | Approx. 300 × 300 × 25 mm |
| Weight | Approx. 1.7 kg |
| Operating conditions | 5–40 °C, 15–90% RH |
| Storage conditions | −20–55 °C, 10–95% RH |
| Ingress protection | IP21 |
| Classification | Type BF applied part, internally powered |
| Standards | ISO 13485, FDA-cleared, CE, RoHS |
FDA-cleared. Transmission logs support Medicare CPT 99453 and 99454 documentation. The controlled specification sheet for your market is issued with the quotation.
SCL-80B
Cellular body fat and weight monitoring with simplified operation for remote clinical tracking.
4G cellularSend your destination market and expected volume — we will confirm pricing, lead time and the regulatory documentation we can supply.